Filter Results By:

Products

Applications

Manufacturers

3 Phase

three voltage waveforms at 120°,1/3 of a cycle offset in time.

See Also: Phase Rotation, Phase


Showing results: 151 - 161 of 161 items found.

  • Solar Analyzers

    Meco Instruments Pvt. Ltd.,

    Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power

  • Audio Test Software

    Soft Hearts LLC

    1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • 60kw off grid power inverter 110/220V split-phase output converter

    SDP-60KW - Zhejiang Sandi Electric Co., Ltd

    Our SDP series Off Grid Pure sine wave inverter is one of the most advanced DC to AC conversion products in the world, it is suitable use for areas without electricity, vehicles, ships, solar energy, wind turbine and other renewable energy systems and etc, can supply power and provide guarantee effectively for the areas with traffic inconveniences, in the mountains, pastoral, border, island and other areas without electricity. It has the main advantages of high quality sine wave AC output, microcomputer control, humanness design, and it is high efficiency and low no-load loss, and no pollution. The inverter can also supply AC power to all kinds of electric equipment, air conditioners, motors, refrigerators, lights, TV, electric fans and other industrial power supply.1. Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more.2. Intelligentized, modularized, simple structure design with powerful function.3. Two kinds of start mode: Step-down Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control.4. The output frequency can be setting via LCD panel, it’s very convenient for customer.5. The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.6. The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.7. Pure sine wave output. With good dynamic response less than 50MS, waveform distortion rate smaller, higher conversion efficiency and stable output voltage.8. Low Frequency Transformer, which ensures that inverter has high efficiency.9. High conversion efficiency, Max. Efficiency≥94%,if 48VDC input,the efficiency can more than 85%.10. Adopts black pure aluminum radiator, which confirms the best radiating performance.11. Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.12. Wide input voltage can be set according to customer’s requirement. Input voltage range can be selected from 150-400V or 300-600V or 400-800V.13. Wide input voltage can work without battery and solar charge controller,save more cost and With MPPT wide voltage input function, maximum use of solar power

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help